1ed0cb970be43e94afde2f7b52472c7f
2 year agoAir To Water Heat Pump
House Heating Pump Water Heater Main Parameters Of Unit:
1. Working mode: cooling, heating(the working mode can be switched according to actual needs)
2. Range of operating frequency: 40Hz~230Hz
3. Range of water setting temperature: heating:30° C ~60° C, cooling: 7° C ~15° C
4. Range of heating capacity of a single unit: 15 kW to 140 kW (customizable)
5. Structure: integral (split type can be customized)
6. Voltage: 380V/3N~/50Hz
7. Range of operating ambient temperature: Cryogenic: above -15° C, Ultra-cryogenic: above -25° C
8. Range of noise: 50~68 dB
Where Is The Best Place To Install An Dhw Heat Pump Water Heater?The higher the ambient temperature, the higher the energy efficiency ratio of the water heater heat pump ; The lower the ambient temperature, the lower the energy efficiency ratio of the heating by heat pump. Therefore, the location of the air source heat pump host needs to absorb more heat energy in the air, usually in a place where it is easier to absorb heat, and the ventilation effect should be good, which air to water heat pump helps the absorption of heat. Therefore, there can be no debris around the heat pump host, which will affect the heat exchange efficiency. So sufficient heat exchange space should be left around the main engine of the geothermal ground source heat pump.
Usually it with 20-30 cm of heat exchange space and maintenance space reserved on the left and right sides and the rear, and more than 2 meters of space in front of the front fan. If there is debris in front of the fan, the cold air cannot spread quickly, and it will be difficult for the heat to gather around the heat exchange fins of the heat pump host for heat exchan ge, which will lead to less heat in the air and affect the heating effect. At this time, it is necessary to pay attention not to be afraid that the outdoor temperature is too low, worry about the low operation efficiency of the heating by heat pump host, or worry about the heat pump host being frozen, so put a cover or warm items on the heat pump host, which will affect the heat exchange efficiency of the heat pump host, and it is easy to bring risks to the fan rotation of the heat pump host.
Similar Video Recommendation
You May Also Like
If you are interested in the product, contact Bossgoovideo.com for more information
- *To:
- GUANGZHOU GENT NEW ENERGY TECHNOLOGY CO., LTD
- *Message:
-
Submit
Main Product:
Swimming Pool Heat Pump,
Heat Pump Water Heater ,
Air to Water Heat Pump,
Air Source Heat Pump,
heating by heat pump,
air conditioning heat pump