Strong wind force of rotatable wall fan
2 year ago
Speaking of workshop cooling equipment, currently, cooling and ventilation are required for large areas of workshop space, and only industrial fans are the ones with a relatively suitable cost performance ratio. The price of industrial fans is relatively affordable, and they can also solve the problem of high temperature in workshops, especially in some stuffy and heavily smelly workshops, with extremely significant effects. For the cooling effect of the production workshop, the rotatable wall fan can achieve a cooling effect of around 4-15 ℃. Although the effect is not as strong and direct as that of traditional air conditioners, the cooling effect brought by environmentally friendly air conditioners is a kind of natural wind, and the natural wind system gives people a feeling that is not the intuitive cold, dry, and dreary feeling of traditional air conditioners, but rather a relatively fresh and comfortable feeling. Moreover, the input cost of HVLS fans is relatively low, and their power consumption is not high, which is 1/8 of that of traditional air conditioners. In some environments where humidity adjustment is required, HVLS fans can effectively adjust humidity, making them a very good cooling and ventilation device.

In order to ensure that the air volume of ventilation equipment and pipes meets the design requirements, air volume regulating valves are installed at different positions of the ventilation pipeline. These regulating valves are basically adjusted upon completion of installation, and should not be arbitrarily moved during maintenance and management. In addition, when the air duct passes through a partition wall with fire protection requirements, a fire damper should be installed. Its function is to automatically close the fire damper once a room in the project catches fire, preventing the fire from spreading along the pipeline. The fire damper is normally open. When the air temperature in the air duct exceeds 70 ℃, the tin wire in the fire damper melts, and the fire damper automatically closes. During maintenance management, do not pull the pull ring of the fire damper to keep it normally open. Check the movable parts of the air outlet and various air volume regulating valves once a quarter, check whether the switches are flexible, whether the valve bolts are loose, and whether the valve body is rusted. If any problems are found, handle them promptly.
Similar Video Recommendation
You May Also Like
If you are interested in the product, contact Bossgoovideo.com for more information
- *To:
- Julai (Chongqing) ventilation equipment Co.,Ltd
- *Message:
-
Submit
Main Product:
Ceiling Fans ,
HVLS fan,
Hvls Ceiling Fans,
Commercial Ceiling Fans,
industrial fan,
Industrial Ceiling Fan
You May Also Like