Off-Grid Solar Inverter
11 month ago
Bosin HM Series Solar Inverter with MPPT controller can choose different types of batteries.High-low voltage protection.Against overload, short-circuit Protection.Over voltage, battery reverse connection(optional).Under-voltage and over-temperature protection. Selectable battery priority or utility priority.AC Grid priority&battery priority working mode are selectable .AC Grid mode: AC Bypass supplies load when AC is normal, battery invert AC Supplies load when AC is Off.
Battery priority: Battery invert supplies load when battery get full-charged; AC Bypass supplies load When battery low and at the meantime battery get charged from solar controller. It transfers back to Battery invert mode when battery gel full charged. It males full use of solar energy and saves electricity.
Product details
MODEL |
HM7kW Pro |
HM8kW |
HM10kW |
|||||
TECHNICAL |
||||||||
BATTERY |
Rated voltage |
48V/96Vdc |
60/96Vdc |
|||||
Charging voltage |
13.8V/27.6V/55.2V |
27.6V/55.2V/110V |
||||||
Charging current |
10~25A |
|||||||
Charging voltage |
55.2Vdc for 48Vdc (*5 for 60Vdc; *8 for 48V, *8 for 96Vdc) battery |
|||||||
Battery high voltage alarm |
60Vdc for 12Vdc (*5 for 48Vdc, *8 for 96Vdc) battery |
|||||||
Battery low voltage alarm |
42Vdc for 12Vdc (*5 for 48Vdc, *8 for 96Vdc) battery |
|||||||
Battery type |
Lithium / gel battery (factory default) |
|||||||
GRID INPUT |
Voltage |
L+N+PE, 220V/230V/240Vac |
||||||
Voltage range |
75~135Vac for 110Vac grid; 145-265Vac for 220Vac grid |
|||||||
Frequency |
50/60Hz (auto-sensing) |
|||||||
PV INPUT |
MPPT optimal voltage |
48V: 60~150Vdc; 60V: 80~220Vdc; 96V: 120~220Vdc |
||||||
MPPT working voltage range |
18~150Vdc for 12V/24V/48V; 120~180Vdc for 96V |
|||||||
Charging current |
MPPT 60A/100A |
|||||||
Maximum PV array power |
For 60A MPPT: 48V/3200W, 60V/4800W, 96V/6000W |
|||||||
|
For 100A MPPT: 48V/5000W, 60V/6000W, 96V/10000W |
|||||||
Maximum PV array voltage |
For 48V: 155Vdc; for 60V: 225Vdc; for 96V: 226Vdc |
|||||||
OUTPUT |
Voltage |
L+N+PE, 110V/120V; 220V/230V/240Vac |
||||||
Frequency |
50/60Hz ±1% (auto-adaptation) |
|||||||
Surge power |
9kVA |
12kVA |
15kVA |
18kVA |
21kVA |
|||
Efficiency |
89% |
90% |
89% |
|||||
Waveform |
Pure sine wave |
|||||||
Protection |
Overvoltage, under voltage, overload, over temperature, surge, short circuit |
|||||||
Display |
LCD+LED |
|||||||
Heat dissipation mode |
Fan |
|||||||
Communication (optional) |
RS232/RS485/App/Wi-Fi |
|||||||
WORKING MODE |
Grid prior |
Working priority is given to grid power, and transfers to battery inverter when grid is abnormal |
||||||
Eco mode |
The device automatically goes into sleep mode when the load is empty |
|||||||
PV prior |
PV first, and when PV is not sufficient, battery and grid complement each other |
|||||||
Environmental |
Humidity |
0%~95% relative humidity (non-condensing) |
||||||
Operating temperature |
-10 ~ 50°C |
|||||||
Storage temperature |
-15 ~ 60°C |
|||||||
PHYSICA. |
Dimension (D*W*H) (mm) |
650x380x800 |
||||||
|
Net weight |
55 |
63 |
72 |
Similar Video Recommendation
You May Also Like
If you are interested in the product, contact Bossgoovideo.com for more information
- *To:
- Bosin Power Limited
- *Message:
-
Submit
Main Product:
Solar Inverter,
Solar Controller,
Solar Power System,
Solar Energy ,
MPPT Controller,
Solar UPS
You May Also Like