frequency converter-1
4 year agoStatic Frequency Converter for Home Appliance Produce.
AC60 series power is a power that change the electric supply into the required voltage and frequency through power converting circuit.Its main characteristic is to supply pure and stable sine wave power output,low harmonic distortion,high-stability frequency and regulation.It can impersonate many of the world of frequency voltage and output characteristics,and cover the whole industry needs,entirely consistent with the design engineer in research and production and testing of the product testing and life, and a simulated tests to a low, import equipment and the production of electricity and other applications.In addition, it will also support the air space and military equipment 400Hz.
The Performance Characteristics
1.Have a
high voltage, over current and short-circuit and overheat warning device
2.16 bit microprocessors, the intelligent control and easy
operation
3.Low distortion interference,input and output are completely isolated , safe
and reliable
4.Unique transient wave forms value control and low distortion, high precision
control
5.Output voltage:low-grade:0-150 V、high grade: 0-300V adjustable continuously
6. Provide world standard grid voltage,frequency,simulation testing all kinds
of electrical products
7.With no radiation,small harmonic ingredients and special treatment,no
distracting
8. Dynamic quick,when load changes in 0 - 100% ,stationary response time
<0.1S
9.A machine has more function,surface and source are one:with the nearest 0.5
level output voltage, current and frequency and power the power factor watch
Technic Parameter:
Model |
13060 |
13100 |
33150 |
33300 |
331000 |
332000 |
334500 |
336000 |
338000 |
3316000 |
|||
Capacity(KVA) |
6 |
10 |
15 |
30 |
100 |
200 |
450 |
600 |
800 |
1600 |
|||
Circuit model |
IGBT/SPWM pulse width adjustment mode |
||||||||||||
Output |
50Hz/60Hz 45-65Hz |
||||||||||||
Load stability |
≤±1% |
||||||||||||
frequency stability |
fixed-frequency≤±0.01%,frequency modulation≤±0.1% |
||||||||||||
Input voltage |
220V±10% |
380V±10% |
|||||||||||
Phase |
single phase |
three phase four wire |
|||||||||||
Wave distortion |
≤3% |
||||||||||||
Output voltage |
1 - 500 V continuous-tuning |
||||||||||||
Reaction time |
≤2mS |
||||||||||||
frequency meter |
0.1Hz |
||||||||||||
Voltage meter |
0.1V |
||||||||||||
Current meter |
0. 1A |
||||||||||||
Power meter |
0.1W |
||||||||||||
Ammeter display |
Frequency, voltage, current, power or PF 4 number display |
||||||||||||
Protection function |
over voltage, over current, over temperature, over load, short circuit, and automatic alarm |
||||||||||||
Insulation reactance |
500Vdc 20MΩ |
||||||||||||
Pressure endurance insulation |
1500Vac/5mA/1min |
||||||||||||
Cooling model |
Compulsive fan cooling |
||||||||||||
Working temperature |
-10℃-45℃ |
||||||||||||
Relative humidity |
0-90%(No condensing) |
||||||||||||
Altitude |
1500meters |
||||||||||||
Dimension (W×L×H)mm |
660*400*700 |
450*900*900 |
500*1100*1100 |
1320*600*1490 |
850*1450*1880 |
1160*1910*1880 |
1260*2000*2080 |
830*3262*2260 |
model |
333000 |
3350000 |
33100000 |
|
Capacity(KVA) |
3000 |
5000 |
10000 |
|
Input |
Voltage |
400V±15% 3phase 4wires or 3phase 5wires |
||
Frequency |
45-65Hz |
|||
Power Factor |
≥0.90 |
|||
Output |
Voltage |
3phase 3 wires ,voltage(300-500V/690)can be chosen |
||
Frequency |
50Hz/60Hz can be chosen |
|||
Frequency Stability |
≤0.01%(0-100% when load are changing,output frequency are not changing ) |
|||
Load Stability |
≤3%(100% pure resistance load) |
|||
Overload Ability |
110% 1hour ,150% 10minutes |
|||
Wave Distortion |
Pure sine wave,THD≤3% |
|||
Efficiency |
≥90%(100% loads) |
|||
Display |
Input/output voltage/ frequency,3phase phase voltage/current,active power .working time.history error etc. |
|||
Control mode |
IGBT/SPWM Pulse width adjustment mode |
|||
Protection Class |
IP54 |
|||
Insulation Reactance |
>2MΩ |
|||
Pressure endurance Insulation |
1800Vac/5Ma/1minute |
|||
Noise Level |
50dBA @1meter |
|||
Cooling Model |
Converter:heat pipe cooling transformer:Compulsive fan cooling |
|||
Protection Function |
The output power supply have perfect protection function of over voltage, over current, short circuit, converter overheat . Consider the different control of the ship's electricity load, when the output load capacity reach the set value,will alarm, so as to control the electricity load |
|||
Environment |
-10℃~+50℃ and 0~90% |
Similar Video Recommendation
You May Also Like
If you are interested in the product, contact Bossgoovideo.com for more information
- *To:
- Jinan Xinyuhua Energy Technology Co.,Ltd
- *Message:
-
Submit
Main Product:
Wind Inverter ,
Off Grid Inverter,
AC Power Source,
Wind Turbine,
Frequency Converter,
Bi Directional Inverter
You May Also Like