COMBO Auto Drain Valve
5 year ago
Air Compressor Tank Auto Drain Valve Jorc Type
This COMBO / COMBO-D-LUX / COMBO-QUICKSET electronic drain valve is the same type of jorc type , used for air compressors, filters, separators, dryers, gas storage tanks, drip feet and other compressed air system components. The electronic automatic drain solenoid valve is matched with an analog analog solid-state electronic timer and a solenoid valve to achieve automatic timing discharge of condensate in the compressed air system. It is widely used in the components of compressed air systems such as screening programs, separators, dryers, gas storage tanks, drip feet, etc. The discharge time and interval can be adjusted according to different needs and the discharge time and interval time. The principle of the electronic drainer is: the opening and closing of the electromagnetic valve, the time and period of automatic drain opening can be adjusted by setting the upper switch.
Technical data of COMBO Air Compressor Auto Drain Valve:
Ref Number
COMBO / COMBO-D-LUX / COMBO-QUICKSET
Type
JORC Type
Medium Temperature:
34 - 131 °F
Ambient Temperature:
34 - 131 °F
Valve Type:
2/2 way, Direct Acting
Orifice Size:
4 mm
Valve Seal:
FPM
Inlet/Outlet Connection:
1/4" (F) & 1/2" (M) NPT / 1/2" NPT
Inlet Connection Height:
0.4"
Valve Housing Material:
Brass or Stainless steel
Power Connection:
DIN 43650A
Deconstruction diagram of Air Compressor Auto Drain Valve:
Timer display of Air Compressor Auto Drain Valve:
Working display of Air Compressor Auto Drain Valve:
How to remove the Auto Drain Valve for water in the air compressor?
In many industries, the requirements for compressed air in air compressors need to be water-free, but air compressors often have water, which causes the air compressors to have water. How to eliminate the use of electronic automatic drain valve?
1. Because there is always water in the air, the so-called humidity, after compression, it will become supersaturated, and the water in the air will be analyzed and become liquid. The moisture content of the compressed air is related to the humidity of the air. If the environment inside the equipment room is too humid, the water content in the air will exceed the standard of use.
2. The automatic drainer of the air compressor itself is blocked or the automatic drainer of the gas storage tank is blocked.
3. The corresponding dryer is not installed or there is no normal work after installation (the drying equipment fails, it is not found and processed in time), and finally the gas compressed by the air compressor is not treated in time, resulting in a large amount of moisture after the removal. Unable to meet normal usage requirements.
4. The post-measures are not sufficient. In the production process where the quality of the compressor gas is very strict, there are generally facilities such as precision filters, and the gas is subjected to a second action to further purify until the production requirements are met.
In order to ensure that the gas quality meets the production process, when there is water in your air compressor, you can check the cause according to the above situation, find out the fault and take remedial measures.
Welcome to your any question and inquiry!
Similar Video Recommendation
You May Also Like
If you are interested in the product, contact Bossgoovideo.com for more information